A Highly Sensitive Glucose Electrode Using Glucose Oxidase Collagen FilmBioelectrochemistry and Bioenergetics, 1978, 5, pp.548-553
Journal articles
hal-01179313v1
|
||
|
Enzyme collagen membrane for electrochemical determination of glucoseAnalytical Chemistry, 1979, 51, pp.96 - 100. ⟨10.1021/ac50037a031⟩
Journal articles
hal-01179308v1
|
||
|
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoringAnalytical and Bioanalytical Chemistry, 1991, 63, pp.1692-1696. ⟨10.1021/ac00017a008⟩
Journal articles
hal-01179862v1
|
||
|
Covalent enzyme coupling on cellulose acetate membranes for glucose sensor developmentAnalytical and Bioanalytical Chemistry, 1988, 60, pp.2781-2786. ⟨10.1021/ac00175a028⟩
Journal articles
hal-01179370v1
|
||
|
TRACE GLUCOSE ELECTRODE FOR CLINICAL, FOOD AND ENVIRONMENTAL DETERMINATIONSANALYTICAL CHEMISTRY SYMPOSIA SERIES - vol. 2. Electroanalysis in hygiene, environmental, clinical and pharmaceutical chemistry, The Electroanalytical Group of the Chemical Society, Chelsea College, University of London, Apr 1979, London, United Kingdom. pp.461-473
Conference papers
hal-01179332v1
|
||
|
245 - A highly sensitive glucose electrode using glucose oxidase collagen filmBioelectrochemistry and Bioenergetics, 1978, 5, pp.548 - 553. ⟨10.1016/0302-4598(87)85047-X⟩
Journal articles
istex
hal-01083001v1
|
||
|
Electrochemical study of reactions at interfaces of glucose oxidase collagen membranesBiochimica et Biophysica Acta (BBA) - Enzymology, 1980, 612, pp.317—327. ⟨10.1016/0005-2744(80)90114-X⟩
Journal articles
istex
hal-01179303v1
|
||
|
The use of microprocessors for the evaluation of the analytical performance of enzyme- based sensorsBiosensors, 1987, 35, pp.705-720
Journal articles
hal-01179639v1
|
||
Implantable glucose sensorUnited States, Patent n° : PCT/US91/02461. 1991
Patents
hal-01084637v1
|
|||
|
A glucose electrode using high-stability glucose-oxidase collagen membranesDiabetes Care, 1982, 5 (3), pp.203 - 206. ⟨10.2337/diacare.5.3.203⟩
Journal articles
hal-01083014v1
|
||
|
Evaluation of Implantable Glucose Enzyme-Based Sensors with Extracorporal Blood ShuntE. F. Pfeiffer. Implantable Glucose Sensors : The State of the Art International Symposium, Reisensburg,, 1987, France. 20, Georg Thieme Verlag Stuttgart : Thieme Medical Publishers, pp.13-16, 1988, Hormone and Metabolic Research
Proceedings